Fiber Optic Splicing Los Angeles CA | Fusion Splicing, Pigtails & Fiber Repair

Fiber Optic Splicing in Los Angeles, CA for Low-Loss Connections & Fast Repairs

Commercial fiber optic splicing for new installations, extensions and emergency repairs. We fusion splice single-mode, multimode and ribbon fiber, organize every splice in protected trays and enclosures, and verify each one on an OTDR so your links stay well within their loss budget.

Fiber cut or need new splices? Call (562) 245-4723 to schedule a splicing crew.

Request a quote

Fiber Optic Splicing Services

A splice joins two fibers so light passes from one to the other with as little loss as possible. Our technicians perform every splice themselves with core-alignment fusion splicers and precision cleavers, following ANSI/TIA-568.3 limits and documenting each splice for your records.

Fusion Splicing

Core Alignment • Low Loss • Permanent Joins

Fiber joined with an electric arc in a core-alignment fusion splicer, creating a permanent, low-loss connection for single-mode and multimode fiber.

Pigtail Splicing for Enclosures

Factory Pigtails • LC / SC • Rack Enclosures

Factory-polished pigtails fusion spliced to every strand inside rack- or wall-mount enclosures, giving each fiber a high-quality connector.

Ribbon & Mass Fusion Splicing

Ribbon Fiber • High Strand Counts • Faster Splicing

Ribbon fiber spliced 12 fibers at a time for high-strand-count backbones and campus cables, cutting time on large jobs.

Emergency Fiber Repair Splicing

Fiber Cuts • OTDR Fault Location • Fast Restoration

Cut or damaged fiber located with an OTDR and repaired with fusion splices at the break, restoring service as quickly as possible.

Fiber Extensions & Re-Routes

Extensions • Re-Routes • Relocations

Existing fiber extended to new rooms, re-routed around construction or relocated with new splices, without replacing the whole run.

Splice Enclosures & Closures

Splice Trays • Rack Enclosures • Outdoor Closures

Splices organized and protected in trays inside rack enclosures, wall boxes or sealed outdoor closures.

Fiber Splicing Components We Install in Los Angeles

  • Single-Mode Fusion Splices
  • Multimode Fusion Splices
  • Ribbon Splices
  • Mechanical Splices
  • Splice Protection Sleeves
  • LC Pigtails
  • SC Pigtails
  • Splice Trays
  • Rack-Mount Splice Enclosures
  • Wall-Mount Splice Boxes
  • Outdoor Splice Closures
  • Slack Storage
  • Fiber Cleaning Supplies
  • Precision Cleavers
  • Splice Records
  • Strand Labels

Good splices start with preparation. Each fiber is stripped, cleaned and cut with a precision cleaver so the end face is perfectly flat, then aligned core to core and fused. A heat-shrink sleeve protects the finished splice, which is laid into a splice tray with its slack neatly coiled, so the fiber is never bent tighter than its minimum radius.

Most of our splicing joins backbone fiber to factory-made pigtails inside enclosures, which gives every strand a precisely polished connector. For high-strand-count cable, we use ribbon fiber and mass fusion splicing to join 12 fibers at a time. When fiber is cut, we locate the break on an OTDR and splice in a repair at the exact spot.

MethodHow it worksTypical lossBest for
Fusion splicingFibers aligned and fused with an electric arcLowest loss, commonly well under 0.1 dBPermanent joins, pigtails, repairs
Ribbon (mass) fusionUp to 12 fibers fused at onceLow loss per fiberHigh-strand-count backbones and campus cable
Mechanical splicingFibers aligned and held in a gel-filled sleeveHigher than fusionTemporary or emergency restoration
TIA-568.3-D limitMaximum allowed loss per splice0.3 dBPass/fail benchmark for every splice
42U network rack in a West LA office IDF with 48-port Cat6A patch panels, horizontal wire managers and an OM4 fiber enclosure
IDF buildout: 42U rack on 19-inch EIA-310 rails, 48-port Cat6A patch panels with 1U horizontal managers, and an LC fiber enclosure fed by OM4 riser backbone.

Fiber Optic Splicing for Commercial Facilities in LA

  • Offices
  • Warehouses
  • Schools
  • Medical Facilities
  • Retail
  • Industrial Facilities
  • Commercial Buildings

We splice fiber in occupied buildings, data rooms and construction sites alike, and we take on a single repair as readily as a full backbone. Work that interrupts live links is scheduled after hours so your business keeps operating. Typical splicing jobs around the city include:

Downtown LA emergency repairs

Riser fiber cut during a neighboring tenant’s buildout, located on the OTDR and spliced back into service the same night.

Century City MDF splicing

High-count backbone fiber spliced to LC pigtails in rack-mount enclosures for a new multi-floor tenant.

Playa Vista campus extensions

Existing campus fiber extended to a new building with splices in a sealed outdoor closure.

Pacoima manufacturing plants

Fiber re-routed around a plant expansion, with new splices instead of replacing the entire run.

Fiber Splicing Problems We Solve for IT Managers in Los Angeles

Cut or damaged fiber

Construction, pests and accidents break fiber. We find the exact break on the OTDR and splice a permanent repair.

High-loss splices

Poor cleaves and old mechanical splices waste loss budget. We re-splice with fusion and verify every joint.

Messy splice enclosures

Loose fibers and overstuffed trays risk breaks. We rebuild enclosures with organized trays and protected slack.

Fiber that’s too short

Moves and expansions leave fiber short of the new room. We extend it with splices instead of replacing the run.

Our Fiber Optic Splicing Process for Our Los Angeles Customers

  1. Assessment

    We review the fiber type, strand count and enclosures, and use an OTDR to locate faults on repair jobs.

  2. Splice plan and quote

    You receive a splice plan showing which strands join where, enclosure work and a schedule, plus an itemized scope.

  3. Fiber preparation

    Cables are opened, fibers are stripped, cleaned and cleaved, and trays and enclosures are prepared.

  4. Fusion splicing

    Each fiber is fused, protected with a sleeve and laid into its tray in strand order.

  5. OTDR verification

    Every splice is measured on the OTDR, and any splice above target is redone on the spot.

  6. Closing and handoff

    Enclosures are closed and labeled, and you receive splice records and OTDR test reports.

Fiber Optic Splicing Testing & Certification

Every splice is verified, not assumed. The splicer’s loss estimate is a first check; the OTDR is the proof. We trace each strand to measure every splice against the TIA-568.3-D limit of 0.3 dB and our much lower working target, and run end-to-end loss tests so the full link is within its budget.

Reports are delivered as PDF files tied to your strand labels, which makes manufacturer warranty registration and future troubleshooting simple.

Technician certifying a Cat6A permanent link at a patch panel and fusion splicing OS2 single-mode fiber in a rack-mount enclosure
Cat6A permanent links are certified to 500 MHz over a maximum of 90 m. Fiber splices are verified on OTDR against the TIA-568.3-D limit of 0.3 dB per splice.

Fiber Optic Splicing Service Area in Southern California

Our office on West Olympic Boulevard puts our crews minutes from the Westside and a short drive to Hollywood, Downtown LA and the South Bay. We splice fiber throughout the city and these nearby cities:

Request a Fiber Optic Splicing Quote

Send us the address, fiber type and strand count, and whether it’s a new installation, extension or repair. For outages, call us directly. We’ll follow up with a splice plan and itemized scope.

We hold a California C-7 state license issued by the Contractors State License Board in Sacramento (CSLB #[NUMBER]).

Los Angeles Telecom Techs
11340 W Olympic Blvd, Los Angeles, CA 90064
Tel: (562) 245-4723
Email: [email protected]

Get low-loss splices and fast fiber repairs, verified on OTDR.

Request a quote
Scroll to Top