Fiber Optic Splicing in Los Angeles, CA for Low-Loss Connections & Fast Repairs
Commercial fiber optic splicing for new installations, extensions and emergency repairs. We fusion splice single-mode, multimode and ribbon fiber, organize every splice in protected trays and enclosures, and verify each one on an OTDR so your links stay well within their loss budget.
Fiber cut or need new splices? Call (562) 245-4723 to schedule a splicing crew.
Request a quoteFiber Optic Splicing Services
A splice joins two fibers so light passes from one to the other with as little loss as possible. Our technicians perform every splice themselves with core-alignment fusion splicers and precision cleavers, following ANSI/TIA-568.3 limits and documenting each splice for your records.
Fusion Splicing
Core Alignment • Low Loss • Permanent Joins
Fiber joined with an electric arc in a core-alignment fusion splicer, creating a permanent, low-loss connection for single-mode and multimode fiber.
Pigtail Splicing for Enclosures
Factory Pigtails • LC / SC • Rack Enclosures
Factory-polished pigtails fusion spliced to every strand inside rack- or wall-mount enclosures, giving each fiber a high-quality connector.
Ribbon & Mass Fusion Splicing
Ribbon Fiber • High Strand Counts • Faster Splicing
Ribbon fiber spliced 12 fibers at a time for high-strand-count backbones and campus cables, cutting time on large jobs.
Emergency Fiber Repair Splicing
Fiber Cuts • OTDR Fault Location • Fast Restoration
Cut or damaged fiber located with an OTDR and repaired with fusion splices at the break, restoring service as quickly as possible.
Fiber Extensions & Re-Routes
Extensions • Re-Routes • Relocations
Existing fiber extended to new rooms, re-routed around construction or relocated with new splices, without replacing the whole run.
Splice Enclosures & Closures
Splice Trays • Rack Enclosures • Outdoor Closures
Splices organized and protected in trays inside rack enclosures, wall boxes or sealed outdoor closures.
Fiber Splicing Components We Install in Los Angeles
- Single-Mode Fusion Splices
- Multimode Fusion Splices
- Ribbon Splices
- Mechanical Splices
- Splice Protection Sleeves
- LC Pigtails
- SC Pigtails
- Splice Trays
- Rack-Mount Splice Enclosures
- Wall-Mount Splice Boxes
- Outdoor Splice Closures
- Slack Storage
- Fiber Cleaning Supplies
- Precision Cleavers
- Splice Records
- Strand Labels
Good splices start with preparation. Each fiber is stripped, cleaned and cut with a precision cleaver so the end face is perfectly flat, then aligned core to core and fused. A heat-shrink sleeve protects the finished splice, which is laid into a splice tray with its slack neatly coiled, so the fiber is never bent tighter than its minimum radius.
Most of our splicing joins backbone fiber to factory-made pigtails inside enclosures, which gives every strand a precisely polished connector. For high-strand-count cable, we use ribbon fiber and mass fusion splicing to join 12 fibers at a time. When fiber is cut, we locate the break on an OTDR and splice in a repair at the exact spot.
| Method | How it works | Typical loss | Best for |
|---|---|---|---|
| Fusion splicing | Fibers aligned and fused with an electric arc | Lowest loss, commonly well under 0.1 dB | Permanent joins, pigtails, repairs |
| Ribbon (mass) fusion | Up to 12 fibers fused at once | Low loss per fiber | High-strand-count backbones and campus cable |
| Mechanical splicing | Fibers aligned and held in a gel-filled sleeve | Higher than fusion | Temporary or emergency restoration |
| TIA-568.3-D limit | Maximum allowed loss per splice | 0.3 dB | Pass/fail benchmark for every splice |
Fiber Optic Splicing for Commercial Facilities in LA
- Offices
- Warehouses
- Schools
- Medical Facilities
- Retail
- Industrial Facilities
- Commercial Buildings
We splice fiber in occupied buildings, data rooms and construction sites alike, and we take on a single repair as readily as a full backbone. Work that interrupts live links is scheduled after hours so your business keeps operating. Typical splicing jobs around the city include:
Riser fiber cut during a neighboring tenant’s buildout, located on the OTDR and spliced back into service the same night.
High-count backbone fiber spliced to LC pigtails in rack-mount enclosures for a new multi-floor tenant.
Existing campus fiber extended to a new building with splices in a sealed outdoor closure.
Fiber re-routed around a plant expansion, with new splices instead of replacing the entire run.
Fiber Splicing Problems We Solve for IT Managers in Los Angeles
Construction, pests and accidents break fiber. We find the exact break on the OTDR and splice a permanent repair.
Poor cleaves and old mechanical splices waste loss budget. We re-splice with fusion and verify every joint.
Loose fibers and overstuffed trays risk breaks. We rebuild enclosures with organized trays and protected slack.
Moves and expansions leave fiber short of the new room. We extend it with splices instead of replacing the run.
Our Fiber Optic Splicing Process for Our Los Angeles Customers
- Assessment
We review the fiber type, strand count and enclosures, and use an OTDR to locate faults on repair jobs.
- Splice plan and quote
You receive a splice plan showing which strands join where, enclosure work and a schedule, plus an itemized scope.
- Fiber preparation
Cables are opened, fibers are stripped, cleaned and cleaved, and trays and enclosures are prepared.
- Fusion splicing
Each fiber is fused, protected with a sleeve and laid into its tray in strand order.
- OTDR verification
Every splice is measured on the OTDR, and any splice above target is redone on the spot.
- Closing and handoff
Enclosures are closed and labeled, and you receive splice records and OTDR test reports.
Fiber Optic Splicing Testing & Certification
Every splice is verified, not assumed. The splicer’s loss estimate is a first check; the OTDR is the proof. We trace each strand to measure every splice against the TIA-568.3-D limit of 0.3 dB and our much lower working target, and run end-to-end loss tests so the full link is within its budget.
Reports are delivered as PDF files tied to your strand labels, which makes manufacturer warranty registration and future troubleshooting simple.
Fiber Optic Splicing Service Area in Southern California
Our office on West Olympic Boulevard puts our crews minutes from the Westside and a short drive to Hollywood, Downtown LA and the South Bay. We splice fiber throughout the city and these nearby cities:
Request a Fiber Optic Splicing Quote
Send us the address, fiber type and strand count, and whether it’s a new installation, extension or repair. For outages, call us directly. We’ll follow up with a splice plan and itemized scope.
We hold a California C-7 state license issued by the Contractors State License Board in Sacramento (CSLB #[NUMBER]).
Los Angeles Telecom Techs11340 W Olympic Blvd, Los Angeles, CA 90064
Tel: (562) 245-4723
Email: [email protected]
Get low-loss splices and fast fiber repairs, verified on OTDR.
Request a quote