Fiber Optic Cabling Services

Fiber carries your network where copper can’t: across floors, between buildings and at speeds well beyond 10 Gbps. Our technicians handle every step of a fiber job themselves, from pulling the cable to the final OTDR trace, following ANSI/TIA-568.3 standards for optical fiber.

Fiber Optic Installation

Single-Mode • Multimode • Riser • Outdoor

Fiber backbone installed between telecom rooms, floors and buildings, using the right fiber type and jacket rating for every run.

  • OS2 single-mode and OM3/OM4 multimode
  • Riser, plenum and outdoor-rated cable
  • Innerduct and conduit pathways
  • Building-to-building campus links

Fiber Optic Splicing

Fusion Splicing • Pigtails • Splice Trays

Fusion splicing that joins fiber with minimal loss, for pigtail terminations, repairs, extensions and carrier handoffs.

  • Fusion-spliced pigtails
  • Mid-span and repair splices
  • Splice trays and enclosures
  • Low-loss joins checked on OTDR

Fiber Termination

LC • SC • MPO • Enclosures

Fiber terminated in rack-mount enclosures with LC, SC or MPO connectors, cleaned, inspected and patched to your equipment.

  • LC, SC and MPO connectors
  • Rack and wall-mount enclosures
  • End-face inspection and cleaning
  • Fiber patch cords to switches

OTDR Testing & Certification

Tier 1 • Tier 2 OTDR • Reports

Loss testing and OTDR traces for every strand, proving each link is within budget and showing every splice and connector.

  • Tier 1 light-source power-meter loss tests
  • Tier 2 OTDR traces
  • Fault location on existing fiber
  • PDF reports by strand

Fiber Optic Infrastructure We Install in Los Angeles

  • OS2 Single-Mode Fiber
  • OM3 Multimode Fiber
  • OM4 Multimode Fiber
  • Riser-Rated Fiber
  • Plenum-Rated Fiber
  • Outdoor & Armored Fiber
  • Innerduct
  • Fusion Splices
  • Pigtails
  • Splice Trays
  • Rack-Mount Enclosures
  • Wall-Mount Enclosures
  • LC & SC Connectors
  • MPO Trunks
  • Fiber Patch Cords
  • Strand Labels

The four fiber services work as one job. Installation puts the right fiber in the right pathway: multimode for runs inside a building, single-mode for long risers and links between buildings. Splicing joins fiber to factory-made pigtails with a fusion splicer for the lowest possible loss. Termination lands every strand in an enclosure on LC, SC or MPO connectors. Testing proves the whole link performs.

We protect fiber at every step: innerduct in shared pathways, rated jackets for risers and plenum ceilings, armored or outdoor cable between buildings, and bend radius respected throughout. We also leave spare strands in every backbone, because adding fiber later costs far more than installing extra now.

Fiber typeCore size10 Gbps reachBest use
OS2 single-mode9 µm10 km and beyondCampus links, carrier entrances, long risers
OM3 multimode50 µm300 mShorter backbone runs within a building
OM4 multimode50 µm400 mMDF-to-IDF risers and data room links
Outdoor / armoredSingle-mode or multimodeDepends on fiber typeBuilding-to-building conduit and yards
42U network rack in a West LA office IDF with 48-port Cat6A patch panels, horizontal wire managers and an OM4 fiber enclosure
IDF buildout: 42U rack on 19-inch EIA-310 rails, 48-port Cat6A patch panels with 1U horizontal managers, and an LC fiber enclosure fed by OM4 riser backbone.

Fiber Optic Cabling for Commercial Facilities in LA

  • Offices
  • Warehouses
  • Schools
  • Medical Facilities
  • Retail
  • Industrial Facilities
  • Commercial Buildings

We install fiber in occupied buildings and new construction alike, and we take on a single splice repair as readily as a campus backbone. Work that affects live links is scheduled after hours so your business keeps operating. Typical fiber jobs around the city include:

Downtown LA high-rise risers

Single-mode and OM4 fiber from the basement MDF to IDFs on every floor, spliced and terminated in each room.

Westwood medical campuses

Outdoor fiber linking clinic buildings and parking structures, carrying both network traffic and camera feeds.

North Hollywood media buildings

High-strand-count fiber between edit suites, data rooms and storage for large media workflows.

Wilmington port logistics yards

Armored fiber to guard shacks, gates and remote offices far beyond copper distance limits.

Fiber Optic Problems We Solve for IT Managers in Los Angeles

Buildings beyond copper’s reach

Runs over 100 m and links between buildings need fiber. We install and terminate it so remote areas join your network.

High-loss or failing links

Dirty connectors and poor splices cause errors. We clean, inspect, re-splice and prove each link with OTDR traces.

Damaged fiber

Construction and pests break fiber. We locate the fault on the OTDR and splice a repair at the exact spot.

Not enough strands

Backbones fill up as networks grow. We add new fiber with spare strands for future expansion.

Our Fiber Optic Cabling Process for Our Los Angeles Customers

  1. Site walk and route survey

    We trace the route between rooms or buildings, measure distances and check pathways, conduit and enclosure space.

  2. Fiber design and quote

    You receive a design with fiber type, strand count, connectors and enclosures, plus an itemized scope and schedule.

  3. Installation

    Fiber is pulled through innerduct, conduit or riser pathways, with bend radius and pulling limits respected.

  4. Splicing and termination

    Strands are fusion spliced to pigtails or terminated on connectors in rack- or wall-mount enclosures.

  5. OTDR testing and certification

    Every strand is loss-tested and traced, and any high-loss event is corrected before close-out.

  6. Labeling and handoff

    Strands and enclosures are labeled, and you receive as-built drawings and test reports for every link.

Fiber Optic Testing & Certification

Every fiber job ends with proof. Tier 1 testing measures total loss against the link’s loss budget, and Tier 2 OTDR testing shows the location and loss of every splice, connector and bend along the run. Connector end faces are inspected and cleaned before testing, since dirt is a leading cause of fiber loss.

Reports are delivered as PDF files tied to your strand labels, which makes manufacturer warranty registration and future troubleshooting simple.

Technician certifying a Cat6A permanent link at a patch panel and fusion splicing OS2 single-mode fiber in a rack-mount enclosure
Cat6A permanent links are certified to 500 MHz over a maximum of 90 m. Fiber splices are verified on OTDR against the TIA-568.3-D limit of 0.3 dB per splice.

Fiber Optic Cabling Service Area in Southern California

Our office on West Olympic Boulevard puts our crews minutes from the Westside and a short drive to Hollywood, Downtown LA and the South Bay. We install fiber optic cabling throughout the city and these nearby cities:

Request a Fiber Optic Cabling Quote

Send us the address, the rooms or buildings you need to connect, approximate distances and the speeds you plan to run. Site plans help. We’ll survey the route and follow up with a fiber design and itemized scope.

We hold a California C-7 state license issued by the Contractors State License Board in Sacramento (CSLB #[NUMBER]).