Access Control Wiring Los Angeles CA | Card Readers, Electric Locks & Door Hardware

Access Control Wiring in Los Angeles, CA for Card Readers, Locks & Secure Doors

Commercial access control wiring for every controlled door. We wire card readers, electric strikes, maglocks, door contacts and request-to-exit devices back to your access panels and lock power supplies, coordinate with your fire alarm system, and test each door until it locks and releases exactly as it should.

Adding card readers or securing more doors? Call (562) 245-4723 for a site walk and itemized quote.

Request a quote

Access Control Wiring Services

A controlled door depends on several devices working together: a reader, a lock, a door contact and a way to exit. Our technicians wire every one of them, terminate them at the panel and test the door as a whole, following the manufacturer’s wiring requirements and the electrical and fire codes for doors.

Card Reader & Keypad Wiring

Wiegand • OSDP • Keypads • Mobile Credentials

Shielded reader cabling to card readers, keypads and mobile-credential readers at entry doors, suites, stairwells and gates.

Electric Strike & Maglock Wiring

Electric Strikes • Maglocks • Electrified Hardware

Lock power wiring to electric strikes, maglocks and electrified hardware, including power transfer hinges and door loops.

Door Position & Request-to-Exit Wiring

Door Contacts • REX Sensors • Exit Buttons

Door position switches and request-to-exit sensors and buttons wired so the system knows when doors open, close and are propped.

Access Panel & Power Supply Terminations

Controllers • Lock Power Supplies • Battery Backup

Every door device terminated at the access control panel and lock power supplies, mounted neatly in the telecom room or a secure closet.

Fire Alarm Interface Coordination

Fire Relay • Fail-Safe Locks • Code Compliance

Lock power interfaced with the fire alarm system, coordinated with your fire alarm contractor, so locked doors release when the alarm activates.

Access Control Rewiring & Upgrades

Wiegand to OSDP • New Readers • Old Wire Removal

Older access control wiring replaced or upgraded for new readers, OSDP communication and additional doors.

Access Control Components We Wire in Los Angeles

  • Card Readers
  • Keypads
  • Reader Cable
  • Composite Access Control Cable
  • Electric Strikes
  • Maglocks
  • Electrified Lever Sets
  • Power Transfer Hinges
  • Door Loops
  • Door Position Switches
  • REX Motion Sensors
  • Exit Buttons
  • Access Control Panels
  • Lock Power Supplies
  • Battery Backup
  • Door & Panel Labels

Each controlled door typically needs four kinds of wiring: reader cable to the card reader, lock power to the strike or maglock, a door position switch, and a request-to-exit device. Many installers use composite access control cable that bundles these in one jacket, which keeps the run neat and the door easy to service. Locks mounted in the door itself get power through a transfer hinge or door loop.

Newer systems increasingly use OSDP, a secure, supervised reader protocol that runs on shielded twisted pair, instead of older Wiegand wiring. On egress doors, we confirm whether each lock should be fail-safe or fail-secure and interface lock power with the fire alarm system through your fire alarm contractor, so doors release when required.

Door deviceTypical cablingWhat it doesConnects to
Card reader (Wiegand)Shielded multi-conductor cableReads credentials and sends them to the panelAccess control panel
Card reader (OSDP)Shielded twisted-pair cableEncrypted, supervised reader communicationAccess control panel
Electric strike or maglockLock power cableLocks and releases the doorLock power supply and panel relay
Door position switchTwo-conductor cableReports door open, closed or heldAccess control panel
Request-to-exit deviceMulti-conductor cableAllows free exit and prevents false alarmsAccess control panel and lock circuit
Electrified door hardwarePower transfer hinge or door loopCarries power through the door to the lockLock power supply
IP reader or door controllerCat6 with PoENetwork-connected reader or controllerPoE switch and access system
42U network rack in a West LA office IDF with 48-port Cat6A patch panels, horizontal wire managers and an OM4 fiber enclosure
IDF buildout: 42U rack on 19-inch EIA-310 rails, 48-port Cat6A patch panels with 1U horizontal managers, and an LC fiber enclosure fed by OM4 riser backbone.

Access Control Wiring for Commercial Facilities in LA

  • Offices
  • Warehouses
  • Schools
  • Medical Facilities
  • Retail
  • Industrial Facilities
  • Commercial Buildings

We wire access control in occupied buildings and new construction alike, and we take on a single door as readily as an entire campus. Work that affects building entry is scheduled after hours so your business stays secure and operating. Typical access control jobs around the city include:

Downtown LA coworking floors

Card readers on suite doors and shared entries, so members reach only the spaces they’ve paid for.

Studio City production offices

Readers and door contacts on edit suites and equipment rooms that protect valuable gear and media.

Highland Park schools

Exterior doors wired to lock on a schedule, with door position switches reporting any door left propped open.

Westchester logistics offices

Readers on dock offices, server rooms and warehouse entries near LAX, wired back to one panel.

Access Control Wiring Problems We Solve for IT Managers in Los Angeles

Doors that won’t lock or release

Undersized lock power, bad splices and loose terminations cause unreliable doors. We trace and fix the wiring.

Constant door-held alarms

Misaligned or miswired door contacts and REX devices trigger false alarms. We correct the wiring and adjustment.

Readers that drop offline

Unshielded or over-length reader runs cause errors. We replace them with proper shielded cable or move to OSDP.

Locks not tied to the fire alarm

We coordinate the fire alarm interface so locked doors release when the alarm activates, as code requires.

Our Access Control Wiring Process for Our Los Angeles Customers

  1. Door survey

    We walk every controlled door, note the frame, hardware and egress requirements, and locate the access panel.

  2. Door schedule and quote

    You receive a door-by-door schedule of readers, locks and devices, with cabling and an itemized scope.

  3. Cabling rough-in

    Installers pull reader, lock, contact and REX cabling from each door back to the panel location.

  4. Device wiring

    Readers, strikes, maglocks, contacts and REX devices are wired at the door, with power transfer for in-door locks.

  5. Panel terminations

    Every device is terminated at the panel and lock power supply, and the fire alarm interface is coordinated.

  6. Door testing and handoff

    Each door is tested for access, locking, release and alarms, and you receive the door schedule and as-built drawings.

Access Control Wiring Testing & Certification

Every controlled door is tested as a complete system before handoff. We check voltage at each lock, confirm the reader reports to the panel, verify the door locks and releases on a valid credential, and test door-forced, door-held and request-to-exit behavior. Network-connected readers and controllers on Cat6 are certified like any data link.

Results are delivered as PDF files with a door schedule and panel map, which makes adding doors and future troubleshooting simple.

Technician certifying a Cat6A permanent link at a patch panel and fusion splicing OS2 single-mode fiber in a rack-mount enclosure
Cat6A permanent links are certified to 500 MHz over a maximum of 90 m. Fiber splices are verified on OTDR against the TIA-568.3-D limit of 0.3 dB per splice.

Access Control Wiring Service Area in Southern California

Our office on West Olympic Boulevard puts our crews minutes from the Westside and a short drive to Hollywood, Downtown LA and the South Bay. We wire access control throughout the city and these nearby cities:

Request an Access Control Wiring Quote

Send us the address, the doors you want to control, the type of lock hardware on each and your access control system brand if you have one. Door photos help. We’ll schedule a door survey and follow up with an itemized scope.

We hold a California C-7 state license issued by the Contractors State License Board in Sacramento (CSLB #[NUMBER]).

Los Angeles Telecom Techs
11340 W Olympic Blvd, Los Angeles, CA 90064
Tel: (562) 245-4723
Email: [email protected]

Get every controlled door wired, tested and secure.

Request a quote